HAD Part Number Index
Consult factory for custom options
ANALOG PROPORTIONAL VALVE DRIVER SERIES
CONNECTOR
H A D
POT
DITHER FREQUENCY ( 050, 100, 130 ETC. )
DI THER
RAMP
CURRENT
CURRENT: Select the current range
that incl udes the maximum desir ed
current.
W = 31mA to 63mA
X = 64mA t o 125mA
Y = 126mA t o 250mA
Z = 251mA t o 500mA
E = 0. 51A t o 1.00A
K = 1. 01A t o 1.67A
G = 1. 68A t o 3.00A
M = 3. 34A t o 5.00A
RAMP: Sel ect the number of r amp
cont rol s. The r amps pot /s are pr eset
to 0 seconds; no adjustments ar e
requi red if ramps are not desired.
S = Singl e r amp pot for al l r amps.
C = I ndividual r amp pot per coil.
T = I ndivi dual ramp pot per dir ection.
R = I ndividual r amp pot per
direction of coi l movement .
POT: Select the type of external potentiometer
desi red for the valve dr iver .
No Let ter = St andar d opti on a non water proof pot
and knob wi ll be pr ovided. Leave t his
box blank.
V = Select the wat er proof pot opt ion. Thi s opt ion
incl udes a number ed bezel and a knob.
CONNECTOR: Select the method
of connect ion desi red.
No Let ter = Ter mi nal block, st andard
option.
Q = Weather Pak Connector Option;
A six- pin tower and a f our- pin
shr oud; on si x inch l eads will be
provided.
DITHER: Select the frequency to
dither the valve. xxx if fr equency in
Hertz. Please use three digits using a
leadi ng 0 if requi red.
N = No Dither added.
Fxxx = Appl y dit her fr equency
of xxx Her tz.
HAD******
D0000x
www.highcountrytek.com
CROSS OVER
MIN A
MIN B
B LIGHT
MAX
RAMP UP A
RAMP DOWN A
RAMP DOWN B
RAMP UP B
DITHER AMP
EXAMPLE PART NUMBER
HADGSF120
3 AMP Dual Coi l Valve Dr iver
with 1 Ramp Pot and 120 Hz
Dither with Adjustable Amplitidude
Figure, 4