023-00354-Rev1.6 evc/epc User Manual 17
Copyright © High Country Tek, Inc. 2013
evc/epc Controller
With SAE J1939 Interface
Output A or B Coil Settings
Select Coil B Active for a Dual
Coil Valve Control.
Enter minimum, maximum
current and dither frequency
according to the valve
specification.
Enter UP or DOWN ramp times.


memory.
Once the system is running, fine
tune these settings.
Always Active (ON) Output A is always active and cannot be .
Coil B active (ON/OFF) Enables/Disables Output B.
Current feedback (ON/OFF)
ONurrent output is monitored and adjusted proportionally to the demand
within the coil max and min settings.
Current Feedback compensates for supply voltage and coil temperature changes. When disabled, 
waveform is adjusted proportionally to the demand between 0% and 100% PWM Duty Cycle.
Inverted (ON/OFF)
ON inversely proportional to the input. This is used with normally closed valves.
When Inverted OFF