023-00354-Rev1.6 evc/epc User Manual 19
Copyright © High Country Tek, Inc. 2013
evc/epc Controller
With SAE J1939 Interface
Ramp Up (1 to 65,000 Mini Seconds) Determines the time for Output A or B to ramp UP from minimum to
maximum current.
Ramp Down (1 to 65,000 Mini Seconds) Determines the time for Output A or B to ramp Down from maximum to
minimum current.
Coil A&B PWM Hz (33 to 500Hz) This is the PWM or Dither frequency according to the valve spec. (Sun
cartridges are 140Hz).
Ignore Open (ON/OFF)
When Ignore Open ONONepc will not declare an error when the output
duty cycle reaches 100%.
OFFON
duty cycle reaches 100%.
OFF have any effect.